210.52(C)(1) Countertops and Work Surfaces. Wall Spaces.

Updates in the Kitchen

Modern residential kitchens have evolved into the heart of the home, complete with custom designs, unique cabinets, and a plethora of material options. Once deemed simple in terms of electrical installation, today's custom kitchen is a puzzle for electricians striving to adhere to the National Electrical Code (NEC). As designs grow in complexity, so do the challenges of aligning the kitchen's aesthetics with the NEC's safety regulations. 

Per NEC's Article 210, specific locations in a dwelling unit kitchen necessitate the installation of receptacle outlets. Yet, some custom designs make it impossible to fit these outlets in compliance with the NEC. The burning question for electricians becomes: What if there's absolutely no way to install a receptacle outlet on a wall servicing a kitchen countertop? 

NEC's Section 210.52(C)(1) offers a glimmer of hope. Addressing the quandary, it lays down the rules for receptacle outlets near countertops and work surfaces, introducing an exception to tackle situations where fitting these outlets becomes unfeasible. Furthermore, Figure 210.52(C)(1) has been refreshed to depict the placement of receptacle outlets adjacent to a kitchen range, sink, or counter-mounted cooking unit. 


Until the 2023 Code cycle, a receptacle outlet was required within 24 inches on each side of any range, counter-mounted cooking unit, or sink installed in a counter space. A new exception allows outlets to be outside of this prescribed area.


2023 NEC - What has changed?

2020 NEC  

In the 2020 NEC, Section 210.52(C)(1) mandates that wall receptacle outlets serving kitchen countertops and workspaces must be positioned so that no point along the wall exceeds a horizontal distance of 24 inches from a receptacle outlet. This requirement translates to needing one outlet within 24 inches of each countertop edge or break, with subsequent receptacle outlets spaced no more than 48 inches apart.

There's an exception that permits electricians to skip installing receptacle outlets behind a range, sink, or counter-mounted cooking unit if it's integrated into a straight section of countertop and the remaining countertop area behind the sink or equipment is less than 12 inches deep. Similarly, no outlets are necessary behind ranges, sinks, or counter-mounted cooking units situated at the corner where two kitchen countertops meet if the countertop area behind that sink or equipment measures less than 18 inches deep. Figure 210.52(C)(1) within the NEC illustrates the required placement and exceptions for these receptacle outlets.

2023 NEC  

In the 2023 NEC, all the prior requirements remain intact, including the well-known exception that often allows electricians to omit receptacle outlets behind sinks and counter-mounted cooking appliances. However, the 2023 NEC introduces a new, second exception. This exception states that if it's impractical to install receptacle outlets in the wall spaces directly beside sinks and counter-mounted cooking appliances, as depicted in Figure 210.52(C)(1), the required outlet(s) can be situated as close as possible to the designated area. This represents a noteworthy addition to the NEC.

Furthermore, the new exception stipulates that the total number of receptacle outlets serving the countertop must meet the requirements set forth in 210.52(C)(1), regardless of whether this new exception is applied. All receptacle outlets serving countertops must adhere to the placement guidelines outlined in Section 210.52(C)(3).


In addition to the fresh exception allowing flexibility in kitchen countertop receptacle placement, the 2023 Code cycle brings revisions to NEC Figure 210.52(C)(1). The original caption has been relocated from below the illustration to become an integral part of the illustration itself. This change enhances clarity in understanding the Figure. Additionally, the Figure now portrays countertop sections as infinite lengths, emphasizing that the length of kitchen countertop sections doesn't affect the application of this Code.


The 2023 Code in Action

The 2023 NEC's Figure 210.52(C)(1) delineates the rules for installing receptacle outlets around a kitchen range, sink, or counter-mounted cooking unit. The recent addition to 210.52(C)(1) bestows electricians with flexibility, granting an alternative means of compliance when the allocated space for an outlet is non-existent. 

To elucidate, outlets must be installed within 24 inches of any sink integrated into a kitchen countertop, as shown in Figure 210.52(C)(1). With the advent of the new Exception No. 2 in 210.52(C)(1), these outlets can be positioned further from the sink's edge if necessary. The only mandate is that they should be as proximate to the sink's edge as possible, without reducing the total number of outlets specified in 210.52(C)(1). 

The world of custom kitchen designs is evolving rapidly. While this presents an array of aesthetic options for homeowners, it simultaneously poses challenges for electricians committed to adhering to the NEC. Thankfully, with the 2023 updates, the NEC has displayed adaptability, ensuring the fusion of design beauty with electrical safety. 

Sample Video Script


[Opening shot: A modern, well-lit custom kitchen with sleek designs. The camera pans over various kitchen elements such as a sink, countertop, and electric outlets.] 

Scott (Narrator): "Custom kitchens – the heart of contemporary homes. But as designs become more intricate, so does the task of wiring them safely and efficiently." 

[Cut to an electrician trying to fit an outlet in a complex kitchen setup.] 

Scott: "Once a straightforward task, today's custom kitchen wiring can feel like solving a jigsaw puzzle. And with the evolving National Electrical Code, or NEC, the rules of this puzzle are constantly updating." 

[Visual: Flashback clips of older kitchens transitioning into modern kitchens.] 

Scott: "Modern residential kitchens aren't just for cooking. They're a fusion of style and function. Yet, their uniqueness can pose challenges for electricians aiming to meet the NEC's safety standards." 

[Visual: Pages of the NEC being flipped.] 

Scott: "NEC's Article 210 sets clear mandates. But what happens when you simply can't fit an outlet on a wall servicing a countertop?" 

[Visual: Graphic representation of the NEC's Section 210.52(C)(1) guidelines.] 

Scott: "Section 210.52(C)(1) addresses this conundrum, guiding the placement of receptacle outlets near countertops and work surfaces. And it's got a brand-new exception for those tricky situations." 

[Transition to the side-by-side comparison: NEC 2020 vs. NEC 2023.] 

Scott: "The 2020 NEC had its own requirements and exceptions, making sure no spot on a kitchen wall was more than 24 inches away from an outlet." 

[Visual: Animation showing the placement of outlets according to the 2020 code.] 

Scott: "Fast forward to 2023, and the NEC introduces added flexibility. A new exception emerges, granting electricians the leeway to place outlets as close as feasible to the recommended spot, when the original placement just doesn't work." 

[Visual: Split screen showing the 2020 vs. 2023 NEC diagrams.] 

Scott: "With the 2023 updates, the NEC's Figure 210.52(C)(1) also gets a facelift. The key changes? A seamlessly incorporated caption and the representation of countertops as infinite lengths." 

[Camera zooms in on the updated NEC diagram.] 

Scott: "So, what does this mean for electricians on the ground? Flexibility. The new exception allows for a balance of aesthetics and safety, ensuring that our modern kitchens remain both stylish and secure." 

[Closing shot: Scott in a modern kitchen, pointing to an electric outlet.] 

Scott: "The world of custom kitchen designs keeps evolving. But with the latest NEC updates, electricians can find that perfect blend of beauty and safety. Here's to beautiful kitchens and the electrical codes that keep them humming!" 

[Fade out with text: "Stay Safe. Stay Updated. NEC 2023."] 